The source indicator confirms where the data that is being displayed is coming from. The options are Keyword (keyword file), Database (actual finite element solution) and Cable (cable pre-static step). For example, the following indicator shows 'Database' for illustration... .
In Keyword mode, the data is coming directly from the keyword file you are working on, meaning you effectively have a model preview facility. Database on the other hand means you are looking at a converged solution. Very occasionally Cable mode is displayed, meaning you are looking at the Cable Pre-Static Step solution. If an initial static analysis fails to converge, it may be that the cable solution is giving a poor approximation to the actual static configuration; viewing the cable solution in that case may help identify modelling shortcomings.