$SUMMARY POSTPROCESSING

<< Click to Display Table of Contents >>

Navigation:  Flexcom > Data Inputs >

$SUMMARY POSTPROCESSING

Previous pageNext page

This section corresponds to the summary postprocessing facility, which allows you to extract pertinent results (e.g. maximum/minimum values) from time domain analyses in succinct tabular format. Refer to Summary Postprocessing for further details.

This section contains the following keywords:

*AXIS/VECTOR is used to define axis systems and vectors for use in postprocessing.

*COLLATE PLOT AXES is used to define a number of key parameters which uniquely identify a particular simulation within a load case matrix. This is a prerequisite for generating 3-dimensional Summary Collation Plots.

*ELEMENT SETS is used to group individual elements into element sets.

*OPTIONS is used to select a number of options relating to summary postprocessing.

*PARA AERODYN is used to request summary output of AeroDyn output where a Flexcom wind turbine analysis has been run in conjunction with the AeroDyn module.

*PARA ANGLE AXIS is used to request summary output of the angle between an element and either a vector or an axis system.

*PARA ANGLE ELEMENT is used to request summary output of the angle between two elements.

*PARA ANGLE TENSION is used to request summary output of angle/tension/pseudo-curvature.

*PARA FORCE is used to request summary output of element restoring forces.

*PARA FORCE ENVELOPE is used to request summary output of statistics of element restoring forces.

*PARA KINEMATIC is used to request summary output of nodal motions.

*PARA REACTION is used to request summary output of nodal reactions.

*PARA SEABED is used to request summary output of statistics of parameters related to seabed contact.

*PARA SERVODYN is used to request summary output of ServoDyn output where a Flexcom wind turbine analysis has been run using the ServoDyn module to control the turbine.

*RESTART is used to indicate that a postprocessing run is to be restarted from an analysis file of different stub name.

*STANDARD OUTPUT is used to quickly request a selection of commonly used outputs.

*TIME is used to specify the time interval over which the summary output statistics are to be calculated.