Overview

Documentation on ServoDyn is incomplete as yet. Further details will soon become available on the ServoDyn website.

ServoDyn Input File Format

The Wind Energy section of the Flexcom examples set contains several sample ServoDyn input files. In order to familiarise yourself with the ServoDyn input file format, you should:

Examine the ServoDyn files in Example L06 - IEA 22MW RWT. There are separate input files for Operational and Parked cases.

Example the OpenFAST documentation on ServoDyn Input Files.

Note that ServoDyn input files must be manually assembled by the user, unlike AeroDyn input files which are automatically generated by Flexcom based on information specified in $AERODYN. Hence a detailed understanding of the ServoDyn input file format is strongly recommended.

Controller DLL input file

The ServoDyn input file references a controller DLL via the DLL_FileName entry. The controller DLL is accompanied by an input file referenced via the DLL_InFile entry. This file contains a set of input parameters which implement controller tuning logic, so it is recommended not to vary the parameters unless you have a strong knowledge of control systems.

SERVODYN OUTPUT Parameters

A list of all possible output parameters for the ServoDyn module is presented below.

Category:

Name:

Description

Convention

Units

Pitch Control

BlPitchC1

Blade 1 pitch angle command

Positive towards feather about the minus zc1- and minus zb1-axes

deg

 

BlPitchC2

Blade 2 pitch angle command

Positive towards feather about the minus zc2- and minus zb2-axes

deg

 

BlPitchC3

Blade 3 pitch angle command

Positive towards feather about the minus zc3- and minus zb3-axes

deg

Generator & Torque Control

GenTq

Electrical generator torque

Positive reflects power extracted and negative represents a motoring-up situation (power input)

kN.m


GenPwr

Electrical generator power

Same sign as GenTq

kW

High Speed Shaft Brake

HSSBrTqC

High-speed shaft brake torque command

Always positive (indicating dissipation of power)

kN.m

Nacelle Yaw Control

YawMomCom or YawMom

Nacelle yaw moment command

About the zn- and zp-axes

kN.m

Nacelle Tuned Mass Damper (TMD)

NTMD_XQ

Nacelle X TMD position (displacement)

Relative to rest position

m


NTMD_XQD

Nacelle X TMD velocity

Relative to nacelle

m/s


NTMD_YQ

Nacelle Y TMD position

Relative to rest position

m


NTMD_YQD

Nacelle Y TMD velocity

Relative to nacelle

m/s

Tower Tuned Mass Damper (TMD)

TTMD_XQ

Tower X TMD position (displacement)

Relative to rest position

m


TTMD_XQD

Tower X TMD velocity

Relative to tower

m/s


TTMD_YQ

Tower Y TMD position

Relative to rest position

m


TTMD_YQD

Tower Y TMD velocity

Relative to tower

m/s