*Section Properties

<< Click to Display Table of Contents >>

Navigation:  Flexcom > Data Inputs > $CODE CHECKING >

*Section Properties

Previous pageNext page

Purpose

To specify section properties to be used in code checking.

Theory

Refer to Code Checking for further information on this feature.

Keyword Format

A block of two lines defining the section and its associated properties. The block may be repeated as often as necessary to define all the required section properties.

SET=Set Name, MATERIAL=Material Name

[Alpha C], [Diameter], [Thickness], [T corr], [Alpha fab], [f0], [Moment factor], [Tension Factor]

Alpha C is calculated as per the relevant DNV standard if unspecified. Diameter and Thickness are obtained from the Flexcom analysis if unspecified. T corr, Alpha fab and Ovality default to 0.0, 0.85 and 0.005, respectively. Moment Factor and Tension Factor default to 1.0.

Table Input

Input:

Description

Set Name:

The name of the element set.

Material Name:

The name of the associated material.

Alpha C:

Flow stress parameter accounting for strain hardening (αc) as per the relevant DNV standard.

Diameter:

The section diameter. This value defaults to the corresponding element outer diameter used in the Flexcom analysis.

Thickness:

The section thickness. This value defaults to the corresponding element wall thickness used in the Flexcom analysis.

T corr:

Corrosion allowance (Tcorr) as per the relevant DNV standard. This value defaults to 0.0 if not specified.

Alpha Fab:

Manufacturing process reduction factor (αfab) as per the relevant DNV standard. This value defaults to 0.85 if not specified.

Ovality:

The section ovality (fo) as per the relevant DNV standard. This value defaults to 0.005 if not specified.

Moment Factor:

Moment scale factor. This value defaults to 1.0 if not specified.

Tension Factor:

Tension scale factor. This value defaults to 1.0 if not specified.