*Load factor
To specify load effect factors to be used in code checking.
Refer to Code Checking for further information on this feature.
A block of three lines to specify the relevant load effect factors:
[FUNCTIONAL=Gamma F]
[ENVIRONMENTAL=Gamma E]
[OPTIMISE=Optimise Option]
Gamma F and Gamma E default to 1.1 and 1.3 respectively. Optimise Option can be YES (the default) or NO.
Input: |
Description |
Functional (Gamma F): |
The functional factor (γf) as per the relevant DNV standard. This value defaults to 1.1 if not specified. |
Environmental (Gamma E): |
The environmental factor (γe) as per the relevant DNV standard. This value defaults to 1.3 if not specified. |
Optimise Factors: |
Option to optimise load factors to maximise load effects. The default value of Yes means that the environmental factor is taken as 1/γe if the environmental loading reduces the combined load effects. |