*Contact Modelling

<< Click to Display Table of Contents >>

Navigation:  Flexcom > Data Inputs > $LOAD CASE >

*Contact Modelling

Previous pageNext page

Purpose

To specify specialised parameters relating to guide surface contact modelling.

Theory

Refer to Contact Modelling for further information on this feature.

Keyword Format

A block of two lines defining the how the contact stiffness is ramped up.

RAMP=Contact Ramp [, POWER=Exponent]

Contact Ramp defaults to 0.0. Exponent defaults to 1.5, but this value is immaterial unless a non-zero value is assigned to Contact Ramp.

Table Input

Input:

Description

Contact Ramp:

The distance over which the contact stiffness is ramped up to its full value. By default, the contact ramp is assumed to be zero, in which case a linear contact model is used.

Exponent:

The exponent to be used in the power-law approximation. This entry is optional and defaults to a value of 1.5 if omitted.