Contact Diameter

<< Click to Display Table of Contents >>

Navigation:  Flexcom > Theory > Model Building > Geometric Properties > Geometric Properties in Flexible Riser Format > Diameter Inputs >

Contact Diameter

Previous pageNext page

The contact diameter (Dc) is the effective diameter for contact calculations, and is relevant only when your Flexcom analysis includes guide surface contact, line clashing or pipe-in-pipe contact. Flexcom uses this input to determine when contact occurs. Specification of a contact diameter is optional, and Dc defaults to the largest of Db, Dd or Do if omitted.