*No Final Static

<< Click to Display Table of Contents >>

Navigation:  Flexcom > Data Inputs > $LOAD CASE >

*No Final Static

Previous pageNext page

Purpose

To suppress the final static analysis step that is typically performed automatically by Flexcom following a frequency domain dynamic analysis.

Theory

Refer to Static Solution for further information on this feature.

Keyword Format

This keyword does not contain any further data.

Table Input

Input:

Description

Suppress Final Static Analysis:

The options are No (the default) and Yes.

Notes

(a)The default is to No. This is the recommended setting for the majority of analyses.

(b)To suppress the final static analysis step, select Yes. In certain rare circumstances where it proves difficult to achieve a converged solution (notwithstanding the effect of varying the solution parameters), then you may wish to suppress the final static analysis step. This means that the current forces may not be entirely accurate, but invoking this option may represent a reasonable compromise. Further details are provided in Static Solution, but it suffices to say that the linearised drag forces due to current loading cannot be evaluated with complete accuracy until after the dynamic response has been found.