Esteel        = 4.32 * 109 lb / ft2

Gsteel        = 1.73 * 109 lb / ft2

Do        = 3.000 ft

Di        = 1.604 ft

A        = π/4*(Do2-Di2) = 5.047 ft2

M        = (Psteel * A) = 76.873 slugs /ft

ρ        = M / A = 15.230 slugs /ft3

Dd        = 3.000 ft

V        = π/4*(Do2) = 7.069 ft2

Db        = 3.000 ft